DF- 40P AIR OPERATED DOUBLE DIAPHRAGM PUMP

  

PERFORMANCE CURVE :

 

DIMENSIONS :

  

III. SPECIFICATIONS:

 

Fluid rate: 45 liter/min

 

Pressure ratio: 1:1

 

Used air pressure: 1.5~3kg/cm2

 

Max.pressure: 7kg/cm2

 

IV. INSTALLATIONS :

1.

Adopt foot stand 53 gallon tank covered with wall mounted & mobile car.

2.

The air inlet must be installed with the air cleaner to prevent dirt from
entering into the air pilot valve and damaging components.

3.

Employ single pipe and prevent dead angles in order to maintain smooth transporting.

4.

The piping length should not exceed more than 10m to ensure proper pressure in transporting.

 

V. HOW TO OPERATE :

1.

Adjust the operating pressure accordingly to the transporting range.

2.

The operating pressure cannot be less than 1.5kg/cm2. If there is a shortage of air
pressure, the pump will not be operated smoothly and it can possibly cause pump to be clogged.

3.

Everyday, the piping system must be cleaned after the work.  Especially,
when the pump is used for heavy viscosity painting.  It is highly recommended that pumps should be cleaned completely for clog-free operation afterward.

 

VI. TROUBLE SHOOTING :

1.

In the case of disassembling the pump for maintenance, shut the air inlet or
 release it and the paint outlet must to be released also.

2.

 

Do not operate pumps under the following conditions:

1. Pumps are clogged.

2. Diaphragms are damaged.

3.

Possible causes when there is no suction force:

 

·        The ball seat is clogged at suction orifice.

·        The suction pipe is damaged, which can reduce paint spraying smoothness.

·        The pump has not been operated for a long time and the paint becomes hardened.  
 

 

 

 

 

 